Panel Upgrade · Washougal, WA ·

Federal Pacific Panel Replaced with a 200-Amp Siemens in Washougal, WA

A Federal Pacific Stab-Lok panel came off the wall of a Washougal home and a 200-amp Siemens went on in its place, re-grounded and bonded, with a Siemens BoltShield surge protector added at the same time.

New Siemens 200-amp electrical panel installed in a Washougal WA home with the dead front removed, showing the 200A main breaker, a Siemens BoltShield surge protector, and every branch circuit landed neatly around the bus

Removed

Federal Pacific Stab-Lok

Installed

Siemens 200-amp

Added

Siemens BoltShield surge protector

Also

Re-grounded and bonded

Scope of Work

  • Removed the original Federal Pacific Stab-Lok load center
  • Installed a 200-amp Siemens panel as a like-and-kind replacement
  • Re-grounded and re-bonded the service
  • Added a Siemens BoltShield whole-house surge protector

Some panel swaps are about capacity. This one in Washougal was about what was already on the wall. The old load center was a Federal Pacific Stab-Lok, and Newman Electric replaced it with a 200-amp Siemens, re-grounded and bonded the service, and added a whole-house surge protector while the panel was open.

Why Federal Pacific panels get replaced on sight

Federal Pacific Electric stopped making residential panels decades ago, and Stab-Lok breakers have a long documented history of failing to trip on an overload or a short. A breaker that does not trip is not a nuisance. It is the one safety device in the circuit deciding not to do its job.

You cannot fix that by swapping breakers, because the breaker and the bus are the problem together. The panel comes out.

The tell is usually right on the door:

  • A “Federal Pacific Electric Company” label, often yellowed, sometimes under a later paint job
  • Stab-Lok branding on the breaker faces inside
  • A catalog number like the L124-40 on this one, printed on the label card

If any of those are in your panel, that is worth replacing a Federal Pacific panel rather than waiting for a reason. It is also worth understanding why a breaker trips, or fails to, because a panel that never seems to trip is not a panel that is working well.

Like and kind, done properly

This was scoped as a like-and-kind replacement, meaning the service size did not change. That does not make it a simple swap. Everything that was landed in the old panel has to come into the new one, identified and terminated, and two things that often get skipped had to be done properly:

  1. Re-grounding and re-bonding. A panel from that era frequently has grounding and bonding that no longer meets current rules, and a replacement is the moment it gets corrected rather than carried forward.
  2. The circuits get sorted, not just moved. The photo of the old panel shows what forty years of additions look like. The new one is landed so the next person can read it.

Surge protection while the panel is open

A Siemens BoltShield surge protective device went in at the same time, sitting right at the bus with its status indicators visible through the dead front.

The argument for doing it during a panel swap rather than later is purely practical: the panel is already open, already de-energized, and already being worked. Adding it as a separate visit means paying for the access twice. Our take on whether whole-house surge protection is worth it covers what it does and does not cover.

Got a Federal Pacific or Zinsco panel in a Washougal or Camas home? Call 360-828-7143 or get the Federal Pacific panel quoted and we will tell you what the replacement involves.

Property details

Older Home (Pre-1980) Federal Pacific Panel

Real Reviews

What customers say about our panel upgrade work

5.0 on Google · 115 reviews
Newman Electric is an easy 5:5! On multiple occasions we have had NE help us with electrical issues. From new light installations in our home to electrical work in our RV. So grateful for the professionalism shown! I highly recommend Newman Electric.
Kari Fassett
Great service with amazing pricing. Installed a 240v outlet 40 amp ckt next to panel my panel and added a 50ka surge protector. Permit included in job cost. Same day installation. Continue the great work!
Semaj H. · Vancouver, WA

Project Photos

More From This Job

Original Federal Pacific Electric Company load center in a Washougal WA home before replacement, with the yellowed catalog label reading Catalog No. L124-40 and a handwritten OVEN tag on the door
The label that names the problem: Federal Pacific Electric Company, catalog L124-40.
Interior of the old Federal Pacific Stab-Lok panel in a Washougal WA home showing crowded branch circuit conductors and the distinctive Stab-Lok breakers before removal
Inside the old panel: Stab-Lok breakers and forty years of circuits crowded around them.

Planning a similar project?

Newman Electric serves Washougal and the rest of Clark and Cowlitz County, WA. Free estimates on every job.

View all recent projects