200-Amp Outdoor Meter Main and RV Circuit in Carson, WA
We put a 200-amp meter main with an outside disconnect on the block wall of this Carson house and fed the existing basement panel from it. We redid the grounding and bonding, added surge protection, cleared out old dead wiring, and ran a 50-amp RV circuit to a new post.
Service
200A single phase
Utility
Skamania PUD
Added
Surge protection
RV Circuit
50A, about 40 ft
Scope of Work
- Put a 200-amp meter main with a disconnect on the outside block wall
- Piped the underground service to Skamania PUD's spec so they could pull their own wire
- Fed the existing basement panel from the new meter main
- Redid the grounding and bonding and added surge protection
- Pulled out old dead-ended conduit and wiring above the panel
- Ran a 50-amp RV circuit about 40 feet to a new post at the corner of the lot
At this house in Carson, out in Skamania County, we put a 200-amp meter main with a disconnect on the outside block wall and fed the existing basement panel from it. While we were there, we ran a 50-amp RV circuit out to the corner of the lot.
Why a meter main outside
A meter main puts the meter and a main breaker in one weatherproof box outside. That breaker is the outside emergency shutoff the 2023 NEC asks for on new services (NEC 230.85), and it’s labeled so a firefighter can find it. It also meant we could keep the basement panel and feed it from outside, instead of tearing it out. Our service and panel upgrades page covers when we keep a panel and when we replace it.
Working with Skamania PUD
Skamania PUD pulls its own service wire. We put in the conduit to their spec so they could pull it in when they were ready. Then we fed the basement panel from the new meter main, redid the grounding and bonding to current NEC and Washington code, and added surge protection.
Clean-up and the RV circuit
- Old wiring out. There was dead-ended conduit and wire hanging above the basement panel. We took it out and removed the circuits that were fed from it.
- RV circuit. We ran a dedicated 50-amp circuit about 40 feet to the southwest corner. The homeowner dug the trench, and we set a post and mounted the RV outlet on it. Our dedicated circuits page has more on these.
If your service is overdue for an upgrade, call 360-828-7143 or tell us how far the meter is from the house.
Real Reviews
What customers say about our panel upgrade work
Great service with amazing pricing. Installed a 240v outlet 40 amp ckt next to panel my panel and added a 50ka surge protector. Permit included in job cost. Same day installation. Continue the great work!
I have to shout out Ryan for going out of his way to come save us tonight. After having an HVAC tech out two days in a row, I was really hoping to have AC restored in my home. What we thought was an HVAC issue turned out to be a breaker issue and we thought we were going to be sweating through the night once again. Newman Electric was the first place I called and I’m super glad I did. Ryan was probably on his way home for the day but diverted over to our house to help us out. He charged a fair rate for emergency service and was in and out in less than 15 minutes. Best part is.. I might actually sleep through the night tonight now that my house is finally cooling down. We’ll be hiring Newman Electric again in the future, as it sounds like we’re due for a panel swap and their pricing is good. As a dispatcher for a local plumbing company, I know good service when I see it. Thanks again Ryan for helping us out tonight! We really owe you one. 10/10 will recommend to friends and family.
Project Photos
More From This Job
More Real Projects
Related Jobs Nearby
Other panel upgrade work and recent projects across Clark and Cowlitz County.

100-Amp to 200-Amp Service Upgrade in Vancouver, WA
This Vancouver house was still on 100-amp service with a crowded old panel. We put a 200-amp Siemens meter main on the outside wall, swapped the inside panel for a new 200-amp Siemens, redid the grounding and bonding, and added whole-house surge protection.

Laundry-Closet Panel Moved Outside to a 200-Amp Meter Main in Vancouver, WA
The old panel in this Vancouver home was inside a laundry closet. We took it out and put a 200-amp Siemens meter main on the outside wall, with a new mast, new grounding, whole-house surge protection, and every circuit extended out to it.

200-Amp Service Relocation and Panel Replacement in Ridgefield, WA
We moved the overhead service on a rural Ridgefield home to the southwest corner, on a new 200-amp meter main with an emergency disconnect. We also replaced the old paint-covered 100-amp basement panel and re-landed every circuit.
Planning a similar project?
Newman Electric serves Carson and the rest of Clark and Cowlitz County, WA. Free estimates on every job.