Kitchen · Vancouver, WA ·

Under-Cabinet Lighting Trimmed Out in Orchards, Vancouver, WA

Under-cabinet lighting trimmed out along a navy and white oak counter run in Orchards, with outlets roughed in for a garage desk and a 20-amp circuit and disconnect set for a garage mini split.

Under-cabinet lighting washing down a white oak counter and fluted wood backsplash beneath navy shaker cabinets in an Orchards home in Vancouver WA

Lighting

Under-cabinet, full counter run

Also Roughed

Garage desk outlets

Mini Split

20-amp circuit with disconnect

Phase

Trim-out after rough-in

Scope of Work

  • Trimmed out under-cabinet lighting along the counter run
  • Roughed in outlets for a garage desk area
  • Ran a 20-amp circuit ten feet along the same wall for a garage mini split
  • Set a disconnect at the mini split location for the HVAC contractor

Under-cabinet lighting is the detail that decides whether a counter run looks finished or looks lit. This trim-out in the Orchards neighborhood put lighting under a navy and white oak run, and dealt with two garage items on the same visit.

Under-cabinet lighting is decided at rough-in

The before photograph is the real story: the channel cut in above the counter line and the boxes set, months before anybody saw a light.

That is when under-cabinet lighting gets decided. Adding it after the cabinets are hung and the backsplash is on means either surface-mounting a cheap strip and running a cord, or opening finished wall. Neither produces the result in the hero photograph, where the light source is invisible and only the wash on the counter shows.

Three things have to be right at rough-in:

  • The supply lands above the counter line and behind where the cabinet will sit
  • The switching is decided, because a run controlled from the wrong place gets used less
  • The fixture type is chosen, since a channel for a linear fixture is not the same cut as a puck

Getting that sequence right is most of what makes kitchen lighting and circuits trim go smoothly.

Lighting the surface, not the room

Under-cabinet lighting is task lighting, and the fluted backsplash here shows exactly why it is worth doing properly. Light grazing down a textured surface picks up the profile of every flute. Light thrown flat at it from a ceiling fixture flattens it out completely.

That is the argument for the fixture sitting at the front edge of the cabinet bottom rather than tucked at the back: you want the light washing down the backsplash and across the counter, not bouncing off the wall behind a toaster.

The garage half of the visit

While the trim was happening, two garage items went in:

  1. Outlets roughed in for a desk area, because a garage that is becoming a workspace needs receptacles where the desk actually goes.
  2. A 20-amp circuit run ten feet along the same wall, with a disconnect, ready for a mini split the HVAC contractor was installing.

That second one is the more useful pattern. Setting the circuit and the disconnect in advance means the HVAC crew arrives to a finished electrical position and hangs their equipment, rather than everybody standing around waiting on a trade that has not been scheduled yet. It is the same coordination we bring to work with general contractors and builders.

Kitchen, pantry or garage conversion coming up in Orchards or east Vancouver? Call 360-828-7143 or sort the lighting at rough-in rather than after the cabinets go on.

Real Reviews

What customers say about our kitchen work

5.0 on Google · 115 reviews
they fixed my kitchen lights - now I need sunglasses - LOL Also installed a great ceiling fan in my family room. Quick, knowledgeable and a painless process
Kit D. · Ridgefield, WA
We recently purchased a different house that had an electric range and we wanted a gas range. We went to go about replacing it. Ordered the new range, got a gas line installed. At the last minute we realized we would need a new plug in to supported a 120 connection. I called the people doing the gas line to get a recommendation for an electrician, they suggested Newman Electric. And boy, am I ever glad they did! I called the number they gave me and was connected to Ryan. He was one of the most responsive, nice people I have ever communicated with. He sent people out the next day. They did a great job! They created the new connection and we are now ready for our new range that's being delivered in 2 days. Awesome customer service! Highly recommend this company. I know they will be our go to for any further electrical issues. Thank you Ryan!
Janice Simmons

Project Photos

More From This Job

Bare drywall wall in an Orchards home in Vancouver WA at rough-in, with device boxes set and the under-cabinet lighting channel cut in above the counter line
Rough-in: boxes set and the lighting run cut in before anything was closed.
Mini split outdoor unit on a pad beside the grey lap siding of an Orchards home in Vancouver WA, with a new disconnect box and line set penetration above it
Outside, with the 20-amp circuit and disconnect ready for the HVAC crew.